What the ALCOR AMSure Gravity Feeding Bag Offers
The ALCOR AMSure Gravity Feeding Bag Set (model ENF1203K) is designed for reliable gravity-based enteral nutrition delivery. Its 1200 mL capacity is suitable for many tube feeding schedules, and the built-in hangers make it easy to suspend from an IV pole or hook. The large top fill opening with a leak-proof cap helps minimize spills during preparation.
Key Features for Setup
- ALCOR® AMSure® Gravity Feeding Bag Set 1200mL(ENF1203K): Secure lock distal tip with a designated locking slot for the G-tube cap reduces unwanted disconnects and cleanup time. The locking mechanism helps keep the feeding tube securely connected during use, which is especially important for gravity feeding where the bag is positioned above the patient.

ALCOR® AMSure® Gravity Feeding Bag Set 1200mL(ENF1203K) - ALCOR® AMSure® Gravity Feeding Bag Set 1200mL(ENF1203K): ENFit connector ensures compatibility with modern enteral feeding devices. ENFit is the current standard for enteral connectors, reducing the risk of misconnection with other tubing systems.
- ALCOR® AMSure® Gravity Feeding Bag Set 1200mL(ENF1203K): Latex and DEHP free construction. Avoids common allergens and plasticizers that may be a concern for some patients.
Setting Up the Gravity Feeding Bag
Follow these general steps for gravity feeding with the ALCOR AMSure bag. Always refer to the manufacturer's instructions provided with the product for specific details.
- Prepare the bag: Remove the bag from its packaging. Open the large top fill opening and pour the prescribed enteral formula into the bag. Secure the leak-proof cap tightly.
- Prime the tubing: Close the roller clamp on the gravity set. Hang the bag from an IV pole or hook using the built-in hangers. Open the clamp and allow formula to flow through the tubing until air is purged, then close the clamp.
- Connect to the feeding tube: Attach the ENFit connector at the distal end of the gravity set to the patient's enteral feeding tube. Ensure the secure lock distal tip is fully engaged and the cap for the G-tube is placed in the designated locking slot.
- Begin feeding: Open the roller clamp to start the flow at the rate prescribed by your healthcare provider. Monitor the bag level and adjust the clamp as needed.
Compatibility and Safety Considerations
The AMSure bag uses an ENFit connector, so it is compatible with ENFit feeding tubes and accessories. The secure lock distal tip includes rounded flanges that reduce wear on the silicone of the G-tube, helping to prolong its life. Note: This product contains a chemical known to the State of California to cause cancer and reproductive harm (see www.P65Warnings.ca.gov). Always follow your healthcare provider's instructions for feeding rate, volume, and frequency.